Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Int Ophthalmol ; 44(1): 9, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38319450

RESUMEN

PURPOSE: The main feature of Graves ophthalmopathy (GO) is revealed by determining the activity and severity of the disease. We aimed to evaluate the use of imaging methods can also provide additional information about the severity of this disease. METHODS: Optical coherence tomography (OCT) and shear wave elastography (SWE) findings were compared in 32 patients with mild GO group and in the healthy control group. Measuring for TSH receptor antibody (TRAb) serum level is used third-generation assay. RESULTS: In Graves group, optic nerve sheath diameter (ONSD) values were increased in both eyes (p < 0.001, p < 0.001). SWE measurements showed a significant increase both eye optic nerve (ON) and right eye soft tissue elasticity values in GO group (p < 0.001, p < 0.001, p < 0.001, respectively). There was a significant thinning in left temporal retinal nerve fiber layer (RNFL) thickness and left RNFL peripapillary thickness in GO group (p < 0.001, p < 0.025, respectively). There was a correlation between left eye OCT and SWE findings. Also, there was a significant difference between the median left eye ON and soft tissue elasticity results in the TRAb-positive GO group (p = 0.049, p = 0.048, respectively). CONCLUSION: SWE measurements showed a significant increase both eyes ONSD, ON and right eye soft tissue elasticity values in GO group. GO group was significant thinning in some left eye regions in OCT measurements. There was a correlation between left eye OCT and SWE findings. In addition to clinical activity score and TRAb, SWE and OCT can be used to monitor in patients with GO.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Oftalmopatía de Graves , Humanos , Tomografía de Coherencia Óptica , Oftalmopatía de Graves/diagnóstico , Retina , Elasticidad
2.
JAMA Psychiatry ; 80(3): 220-229, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36630119

RESUMEN

Importance: Adverse posttraumatic neuropsychiatric sequelae after traumatic stress exposure are common and have higher incidence among socioeconomically disadvantaged populations. Pain, depression, avoidance of trauma reminders, reexperiencing trauma, anxiety, hyperarousal, sleep disruption, and nightmares have been reported. Wrist-wearable devices with accelerometers capable of assessing 24-hour rest-activity characteristics are prevalent and may have utility in measuring these outcomes. Objective: To evaluate whether wrist-wearable devices can provide useful biomarkers for recovery after traumatic stress exposure. Design, Setting, and Participants: Data were analyzed from a diverse cohort of individuals seen in the emergency department after experiencing a traumatic stress exposure, as part of the Advancing Understanding of Recovery After Trauma (AURORA) study. Participants recruited from 27 emergency departments wore wrist-wearable devices for 8 weeks, beginning in the emergency department, and completed serial assessments of neuropsychiatric symptoms. A total of 19 019 patients were screened. Of these, 3040 patients met study criteria, provided informed consent, and completed baseline assessments. A total of 2021 provided data from wrist-wearable devices, completed the 8-week assessment, and were included in this analysis. The data were randomly divided into 2 equal parts (n = 1010) for biomarker identification and validation. Data were collected from September 2017 to January 2020, and data were analyzed from May 2020 to November 2022. Exposures: Participants were recruited for the study after experiencing a traumatic stress exposure (most commonly motor vehicle collision). Main Outcomes and Measures: Rest-activity characteristics were derived and validated from wrist-wearable devices associated with specific self-reported symptom domains at a point in time and changes in symptom severity over time. Results: Of 2021 included patients, 1257 (62.2%) were female, and the mean (SD) age was 35.8 (13.0) years. Eight wrist-wearable device biomarkers for symptoms of adverse posttraumatic neuropsychiatric sequelae exceeded significance thresholds in the derivation cohort. One of these, reduced 24-hour activity variance, was associated with greater pain severity (r = -0.14; 95% CI, -0.20 to -0.07). Changes in 6 rest-activity measures were associated with changes in pain over time, and changes in the number of transitions between sleep and wake over time were associated with changes in pain, sleep, and anxiety. Simple cutoffs for these biomarkers identified individuals with good recovery for pain (positive predictive value [PPV], 0.85; 95% CI, 0.82-0.88), sleep (PPV, 0.63; 95% CI, 0.59-0.67, and anxiety (PPV, 0.76; 95% CI, 0.72-0.80) with high predictive value. Conclusions and Relevance: These findings suggest that wrist-wearable device biomarkers may have utility as screening tools for pain, sleep, and anxiety symptom outcomes after trauma exposure in high-risk populations.


Asunto(s)
Dispositivos Electrónicos Vestibles , Muñeca , Adulto , Femenino , Humanos , Masculino , Ansiedad , Dolor , Sueño
3.
Ocul Immunol Inflamm ; 31(4): 682-688, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35830240

RESUMEN

PURPOSE: To describe the management and outcome of two extremely rare and painful cases of Mooren's ulcer, an idiopathic peripheral autoimmune-associated ulcerative corneal disease. METHODS: Case report with literature review on the management of ocular inflammation in Mooren's ulcer. RESULTS: A 47-year-old female and a 76-year-old female presented with progressive bilateral Mooren's ulcer that were refractory to conventional immunosuppressive therapy. Following treatment with infliximab, an anti-tumor necrosis factor alpha, a significant improvement in disease progression was observed, with no corneal thinning or perforation at follow-ups. CONCLUSION: This case report highlights how infliximab can be effective in cases with Mooren's ulcer refractory to conventional therapies.


Asunto(s)
Úlcera de la Córnea , Úlcera , Femenino , Humanos , Persona de Mediana Edad , Anciano , Infliximab/uso terapéutico , Úlcera/diagnóstico , Úlcera/tratamiento farmacológico , Inmunosupresores/uso terapéutico , Úlcera de la Córnea/diagnóstico , Úlcera de la Córnea/tratamiento farmacológico , Córnea/patología
4.
Taiwan J Ophthalmol ; 13(4): 520-526, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38249509

RESUMEN

PURPOSE: To assess the optic disc and retinal microvasculature by optical coherence tomography angiography (OCTA) in asthmatic children. MATERIALS AND METHODS: Thirty asthmatic children (asthma group) and 30 control age- and sex-matched healthy controls (control group) were included in this cross-sectional study. The asthma group was then divided into two subgroups according to the presence of inhaled steroid use. Demographic findings were noted. Retinal nerve fiber layer (RNFL) thickness and vessel density in different sections of the retina and optic nerve head were analyzed by OCTA. RESULTS: RNFL thickness for temporal quadrants and flow area for outer retina levels were significantly lower in the asthma group than the control group (72.58 ± 10.99 µm vs 77.73 ± 9.73µm, P = 0.015, and 0.60 ± 0.31mm2 vs. 0.72 ± 0.31mm2, P = 0.047, respectively). However, inside disc vascular densities were significantly higher in the asthma group when compared to controls (55.16% ± 3.71% vs. 52.08% ± 3.79%, P < 0.001). Inside disc vascular densities were also significantly higher, and RNFL thickness for temporal quadrants was significantly lower in the asthmatic patients without steroid use subgroup when compared to others (P < 0.001, P = 0.012, respectively). CONCLUSION: Lower values of temporal quadrant RNFL, and flow area for outer retina, but higher levels of inside disc vascular density seem to be associated with asthmatic children. OCTA findings in asthmatic children appear to be regardless of inhaled steroid use.

5.
Alpha Psychiatry ; 23(5): 253-261, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36426270

RESUMEN

Objective: The aim of this study is to investigate the retinovascular structure of schizophrenia patients using optical coherence tomography angiography (OCTA). Methods: 47 eyes of schizophrenia patients were compared with 50 eyes of demographically matched healthy controls in terms of OCTA measurements. Schizophrenia patients were evaluated in two groups as short-term (≤ 5years) and long-term (> 5years) according to the time elapsed after the diagnosis of schizophrenia. Results: Schizophrenia patients showed overall thinning of retinal nerve fiber layer and macula, and lower vessel density (VD) compared to controls. The results were significant for thickness measurements of general macula and for VD in specific areas (P < 0.05); however, they were not significant for the RNFL measurements except the mean circumpapillary RNFL, which was noted to approach significance (P = 0.055). Long-term patients showed significantly lower VD in the whole and perifoveal region of superficial capillary plexus, the whole, perifoveal and foveal region of deep capillary plexus, and the whole area and the disc of radial peripapillary capillaries compared to short-term patients (P = 0.014, P = 0.009, P = 0.011, P = 0.010, P = 0.011, P = 0.035, P = 0.030). Conclusions: These findings suggest that schizophrenia may be a neurodegenerative disease with progressive microvascular involvement over the years, and that OCTA has the potential to be a useful tool in detecting retinovascular changes in patients with schizophrenia.

6.
JMIR Form Res ; 6(8): e36972, 2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36001367

RESUMEN

BACKGROUND: Heart failure (HF) is a major cause of frequent hospitalization and death. Early detection of HF symptoms using smartphone-based monitoring may reduce adverse events in a low-cost, scalable way. OBJECTIVE: We examined the relationship of HF decompensation events with smartphone-based features derived from passively and actively acquired data. METHODS: This was a prospective cohort study in which we monitored HF participants' social and movement activities using a smartphone app and followed them for clinical events via phone and chart review and classified the encounters as compensated or decompensated by reviewing the provider notes in detail. We extracted motion, location, and social interaction passive features and self-reported quality of life weekly (active) with the short Kansas City Cardiomyopathy Questionnaire (KCCQ-12) survey. We developed and validated an algorithm for classifying decompensated versus compensated clinical encounters (hospitalizations or clinic visits). We evaluated models based on single modality as well as early and late fusion approaches combining patient-reported outcomes and passive smartphone data. We used Shapley additive explanation values to quantify the contribution and impact of each feature to the model. RESULTS: We evaluated 28 participants with a mean age of 67 years (SD 8), among whom 11% (3/28) were female and 46% (13/28) were Black. We identified 62 compensated and 48 decompensated clinical events from 24 and 22 participants, respectively. The highest area under the precision-recall curve (AUCPr) for classifying decompensation was with a late fusion approach combining KCCQ-12, motion, and social contact features using leave-one-subject-out cross-validation for a 2-day prediction window. It had an AUCPr of 0.80, with an area under the receiver operator curve (AUC) of 0.83, a positive predictive value (PPV) of 0.73, a sensitivity of 0.77, and a specificity of 0.88 for a 2-day prediction window. Similarly, the 4-day window model had an AUC of 0.82, an AUCPr of 0.69, a PPV of 0.62, a sensitivity of 0.68, and a specificity of 0.87. Passive social data provided some of the most informative features, with fewer calls of longer duration associating with a higher probability of future HF decompensation. CONCLUSIONS: Smartphone-based data that includes both passive monitoring and actively collected surveys may provide important behavioral and functional health information on HF status in advance of clinical visits. This proof-of-concept study, although small, offers important insight into the social and behavioral determinants of health and the feasibility of using smartphone-based monitoring in this population. Our strong results are comparable to those of more active and expensive monitoring approaches, and underscore the need for larger studies to understand the clinical significance of this monitoring method.

7.
Indian J Ophthalmol ; 70(5): 1669-1677, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35502048

RESUMEN

Purpose: To evaluate the retinal and optic disc microvascular changes according to disease severity in patients with stable chronic obstructive pulmonary disease (COPD), and the correlation of pulmonary parameters with optical coherence tomography angiography (OCTA) findings. Methods: Forty patients with COPD and 30 age- and sex-matched subjects (control group) were included in this cross-sectional prospective study. The COPD group was then divided into two subgroups according to GOLD classification and disease severity as mild-to-moderate COPD group (group 1) and severe COPD group (group 2). OCTA was performed with 6 mm × 6 mm sections for the macula and 4.5 mm × 4.5 mm sections for the optic disc. Foveal retinal thickness (FRT), peripapillary retinal nerve fiber layer (RNFL) thickness, and vessel density in different sections of the retina and optic disc were analyzed. Results: The mean ages, gender, intraocular pressures, peripapillary RNFL thickness, FRT, and optic disc vessel densities were similar among the groups. Compared to the control group and group 1, group 2 showed significantly lower mean foveal vessel density measurements in superficial and deep capillary plexus (P = 0.014 and P = 0.007, respectively). Cigarette packets/year, exacerbation per year, and Modified Medical Research Council showed significant negative correlations, whereas forced expiratory volume in 1 s (FEV1) and FEV1/forced vital capacity showed significant positive correlations with foveal vessel densities. Conclusion: COPD severity seems to have a negative effect on OCTA measurements. OCTA may reflect the severity of inflammation and hypoxia in COPD and may provide useful detailed information on the role of retinal vascular changes in the follow-up and progression of patients with COPD.


Asunto(s)
Disco Óptico , Enfermedad Pulmonar Obstructiva Crónica , Estudios Transversales , Angiografía con Fluoresceína/métodos , Humanos , Microvasos , Disco Óptico/irrigación sanguínea , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Vasos Retinianos , Tomografía de Coherencia Óptica/métodos
8.
Sleep Biol Rhythms ; 20(2): 267-273, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38469251

RESUMEN

To identify and compare changes in intraocular pressure (IOP), macular, and peripapillary retinal nerve fiber layer (RNFL) thickness using optical coherence tomography (OCT) measurements before and after 3 months of positive airway pressure (PAP) therapy in patients with severe obstructive sleep apnea syndrome (OSAS). Twenty-five patients diagnosed with severe OSAS in the neurology sleep outpatient clinic were included in the study. Ophthalmologic examinations were performed at the time of diagnosis and after 3 months of PAP therapy. Statistical analysis of comparisons of pre-treatment and post-treatment measurements of IOP and OCT was performed. Before the PAP therapy, the correlations between central corneal thickness (CCT), body mass index (BMI), OCT, IOP, and sleep parameters were statistically analyzed. Compared to the pre-treatment measurements at the time of diagnosis, post-treatment measurements showed insignificant decrease in IOP, significant increase in mean macular thickness and significant thinning in superior nasal RNFL. There was no correlation found between pre-treatment measurements including IOP, OCT, CCT, BMI, and sleep parameters. The effect of intermittent hypoxia and hypercapnia on the IOP and macula may be reversible in severe OSAS patients receiving 3 months of PAP therapy, but the reversibility of the neurodegenerative effects of OSAS on RNFL with this treatment seems controversial. OCT can be considered to be a promising technique for monitoring disease progression under PAP therapy in patients with severe OSAS.

9.
Int Ophthalmol ; 41(11): 3615-3622, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34432177

RESUMEN

PURPOSE: To evaluate the association of systemic immune-inflammation index (SII) levels, neutrophil/lymphocyte ratio (NLR), and platelet/lymphocyte ratio (PLR) with severity of noninfectious uveitis. METHODS: This retrospective study included 46 patients with noninfectious uveitis (uveitis group) and 46 age- and sex-matched healthy subjects (control group). The demographic and ocular findings, localization, and activity of uveitis were recorded at the time of onset evaluation. SII, NLR, and PLR levels of patients were compared between the groups. RESULTS: SII, NLR, and PLR levels were significantly higher in uveitis group when compared to control group (p < 0.001, p = 0.005, and p = 0.001, respectively). While SII and NLR were significantly higher in severe anterior uveitis than mild anterior uveitis (p = 0.006 and p = 0.021, respectively), only SII was significantly higher in severe posterior and panuveitis than mild ones (p = 0.038). CONCLUSION: SII, as a novel inflammation index, may be more significant tool than NLR and PLR in determining the severity of the uveitis. Furthermore, SII may be a potential useful index in clinical practice to follow-up and manage these patients by monitoring response to anti-inflammatory treatment modalities.


Asunto(s)
Linfocitos , Uveítis , Humanos , Inflamación , Neutrófilos , Estudios Retrospectivos , Uveítis/diagnóstico
10.
Neurol Sci ; 42(10): 4387-4390, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33763810

RESUMEN

Hospital visits and regular rehabilitation of chronic patients due to COVID-19 pose a risk. Therefore, patients with chronic illnesses who need regular rehabilitation have been victims of the pandemic process. Because of their fear of being infected, they were deprived of the chance of their symptoms being rehabilitated. Therefore, it is extremely important to rehabilitate individuals with chronic illnesses in need of rehabilitation through telerehabilitation. In this study, we aimed to show the effect of Cawthorne-Cooksey exercises to be applied through telerehabilitation on eye movements, vision, and quality of life in a patient suffering from diplopia due to multiple sclerosis (MS). It has been found that Cawthorne-Cooksey exercises improve the quality of life and reduce the complaints of diplopia in MS patients with diplopia. In addition, the patient verbally stated that his balance increased after Cawthorne-Cooksey exercises. As a result, Cawthorne-Cooksey exercises are a rehabilitation method that gives positive results in the treatment of diplopia and it is recommended to apply this method via telerehabilitation.


Asunto(s)
COVID-19 , Esclerosis Múltiple , Telerrehabilitación , Diplopía/etiología , Humanos , Esclerosis Múltiple/complicaciones , Pandemias , Calidad de Vida , SARS-CoV-2
11.
Physiol Meas ; 42(4)2021 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-33761477

RESUMEN

Objective.To develop a sleep staging method from wrist-worn accelerometry and the photoplethysmogram (PPG) by leveraging transfer learning from a large electrocardiogram (ECG) database.Approach.In previous work, we developed a deep convolutional neural network for sleep staging from ECG using the cross-spectrogram of ECG-derived respiration and instantaneous beat intervals, heart rate variability metrics, spectral characteristics, and signal quality measures derived from 5793 subjects in Sleep Heart Health Study (SHHS). We updated the weights of this model by transfer learning using PPG data derived from the Empatica E4 wristwatch worn by 105 subjects in the 'Emory Twin Study Follow-up' (ETSF) database, for whom overnight polysomnographic (PSG) scoring was available. The relative performance of PPG, and actigraphy (Act), plus combinations of these two signals, with and without transfer learning was assessed.Main results.The performance of our model with transfer learning showed higher accuracy (1-9 percentage points) and Cohen's Kappa (0.01-0.13) than those without transfer learning for every classification category. Statistically significant, though relatively small, incremental differences in accuracy occurred for every classification category as tested with the McNemar test. The out-of-sample classification performance using features from PPG and actigraphy for four-class classification was Accuracy (Acc) = 68.62% and Kappa = 0.44. For two-class classification, the performance was Acc = 81.49% and Kappa = 0.58.Significance.We proposed a combined PPG and actigraphy-based sleep stage classification approach using transfer learning from a large ECG sleep database. Results demonstrate that the transfer learning approach improves estimates of sleep state. The use of automated beat detectors and quality metrics means human over-reading is not required, and the approach can be scaled for large cross-sectional or longitudinal studies using wrist-worn devices for sleep staging.


Asunto(s)
Dispositivos Electrónicos Vestibles , Muñeca , Estudios Transversales , Electrocardiografía , Frecuencia Cardíaca , Humanos , Aprendizaje Automático , Fotopletismografía , Sueño , Fases del Sueño
12.
Acta Trop ; 218: 105907, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33789154

RESUMEN

PURPOSE: Toxoplasma gondii is an intracellular parasite that can affect all vertebrae and is the causative agent of toxoplasmosis. At present, the United States CDC (Centers for Disease Control and Prevention) recognizes this infection as a neglected disease. Toxoplasma gondii infection profiles exhibit differences because of the different regional and climatic responses to these parasites in Turkey, and these protozoan infections are notably common in this country. In this study, we attempted to obtain the whole-genome sequence of T. gondii using next-generation sequencing technology. METHODS: Toxoplasma gondii isolates were isolated from an infant with congenital toxoplasmosis by Ekmen et al. (1974) in Ankara, Turkey. Whole-genome sequencing (WGS) was performed using the Illumina HiSeq 2500 and HiSeq SBS Kit v2. A T. gondii library was created on this device in the initial stage. After the completion of the library phase, sequence analysis was begun with a next-generation sequencing device. The resulting fragments were combined using paired-end (PE) reading and converted into a single DNA fragment. Bioinformatic analysis was performed using the Geneious 2.1. RESULTS: In our study, WGS was successfully performed on T. gondii. The T. gondii whole-genome sequence has a coverage value of 50x, a size of 61,5763 Mb and a GC ratio of 52.6%. Data from this sequence were submitted to the National Center for Biotechnology Information (NCBI) GenBank (www.ncbi.nlm.nih.gov) database under the name Toxoplasma gondii TR01 (TG_TR01). The accession number of the genome obtained in this study is WOEV00000000.1. The biological sample access number is SAMN13338796. The genome of the T. gondii strain obtained in this study was compared with the reference genome, and 8312 CDSs (coding sequences), 183 tRNAs, 294 rRNAs and 8789 genes were identified. Among the 8312 CDSs, 4284 encoded hypothetical proteins (hypothetical protein CDSs/proteins of unknown function). The entire genome sequence of T gondii TR01 was compared with that of Toxoplasma gondii ME49. The results of this comparison demonstrate that the analyzed genome was 99,98% similar to the reference genome. The accession numbers of 14 chromosomes belonging to the genome sequences of T. gondii TR01 (TG_TR01) are CM019722.1, CM019723.1, CM019724.1, CM019725.1, CM019726.1, CM019727.1, CM019728.1, CM019729.1, CM019730.1, CM019731.1, CM019732.1, CM019733.1, CM019734.1, and CM019735.1. CONCLUSION: In this study, a whole-genome sequences of T. gondii was conducted for the first time in Turkey. The analyzed strain was named T. gondii TR01. The data obtained from this study may contribute to a better understanding of T. gondii. T. gondii is an important pathogen with an unusual population structure. Although T. gondii is highly zoonotic and has a complicated life cycle, some strains of this parasite have exhibited high genetic sequence similarity, and our study supports this knowlegde. The characterization of this strain may be very useful for the scientific community of our country and may help to establish a foundation for further research investigating the genome of T. gondii.


Asunto(s)
Toxoplasma/genética , Toxoplasmosis Congénita/parasitología , Animales , Biología Computacional , ADN Protozoario , Biblioteca de Genes , Genoma de Protozoos , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Lactante , Ratones , Análisis de Secuencia de ADN , Turquía , Secuenciación Completa del Genoma
13.
J Pediatr Endocrinol Metab ; 34(2): 171-176, 2021 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-33544543

RESUMEN

OBJECTIVES: To investigate the optical coherence tomography angiography (OCTA) and specular microscopy (SM) findings in obese children and compare them with healthy ones. METHODS: In this prospective study, 50 eyes of 25 obese children [body mass index (BMI) ≥95th percentile], 36 eyes of 18 control age- and sex- matched healthy subjects (BMI <85th percentile) were included. Demographic features and ophthalmological examination including OCTA measurements as well as SM findings were assessed. Cellular morphology was observed by noncontact SM and results for corneal endothelial cell density (cells/mm2), coefficient of variation of cell size and percentage of hexagonal cells were obtained. The OCTA was performed with 6 × 6 mm sections for macula and 4.5 × 4.5 mm sections for optic disc in all eyes. Foveal retinal thickness (FRT), retinal nerve fiber layer (RNFL) thickness, vessel density in different sections of retina and optic nerve head were analyzed. RESULTS: All SM parameters, RNFL thickness for average, and all quadrants and optic disc radial peripapillary capillary densities were similar between groups. However, FRT, flow area for choriocapillaris, superficial and deep foveal capillary densities were significantly higher in obese group when compared to controls (242.4 ± 18.2 µm vs. 232.1 ± 16.5 µm, p=0.024, 2.2 ± 0.1 mm2 vs, 2.2 ± 0.0 mm2, p=0.042, 22.4 ± 6.9% vs. 15.6 ± 5.5%, p=0.001, and 38.9 ± 7.5% vs. 31.1 ± 8.6 %, p=0.001, respectively). CONCLUSIONS: Obese children seem to have higher values of FRT, flow area for choriocapillaris, superficial and deep foveal capillary densities. These results may have significant implications for understanding of how childhood obesity could affect retinal microvasculature.


Asunto(s)
Endotelio Corneal/patología , Microvasos/patología , Obesidad Infantil/fisiopatología , Vasos Retinianos/patología , Adolescente , Estudios de Casos y Controles , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Pronóstico , Estudios Prospectivos
14.
IEEE J Biomed Health Inform ; 25(8): 2866-2876, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33481725

RESUMEN

Post-Traumatic Stress Disorder (PTSD) is a psychiatric condition resulting from threatening or horrifying events. We hypothesized that circadian rhythm changes, measured by a wrist-worn research watch are predictive of post-trauma outcomes. APPROACH: 1618 post-trauma patients were enrolled after admission to emergency departments (ED). Three standardized questionnaires were administered at week eight to measure post-trauma outcomes related to PTSD, sleep disturbance, and pain interference with daily life. Pulse activity and movement data were captured from a research watch for eight weeks. Standard and novel movement and cardiovascular metrics that reflect circadian rhythms were derived using this data. These features were used to train different classifiers to predict the three outcomes derived from week-eight surveys. Clinical surveys administered at ED were also used as features in the baseline models. RESULTS: The highest cross-validated performance of research watch-based features was achieved for classifying participants with pain interference by a logistic regression model, with an area under the receiver operating characteristic curve (AUC) of 0.70. The ED survey-based model achieved an AUC of 0.77, and the fusion of research watch and ED survey metrics improved the AUC to 0.79. SIGNIFICANCE: This work represents the first attempt to predict and classify post-trauma symptoms from passive wearable data using machine learning approaches that leverage the circadian desynchrony in a potential PTSD population.


Asunto(s)
Trastornos por Estrés Postraumático , Ritmo Circadiano , Estudios de Cohortes , Humanos , Curva ROC , Trastornos por Estrés Postraumático/diagnóstico , Muñeca
15.
Sleep Breath ; 25(2): 843-848, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33095416

RESUMEN

BACKGROUND: Obstructive sleep apnea syndrome (OSAS) is characterized by recurrent episodes of hypoxemia and hypercapnia during sleep. The aim of this study was to determine whether OSAS causes significant changes in corneal endothelium detectable by specular microscopy. METHODS: This prospective, cross-sectional study compared the specular microscopic features of the corneal endothelium of patients with OSAS and age-and gender-matched controls. Patients diagnosed with OSAS by polysomnography in the sleep unit were classified using apnea-hypopnea indexes into two groups as mild-moderate OSAS group and severe OSAS group. All participants were divided into three age groups: 30-45, 46-60, and > 60 years. Corneal endothelial cell density (ECD), percentage of hexagonal cells (Hex), and coefficient of variation of cell area (CV) were obtained using a non-contact specular microscope. The measurements of each group were compared statistically. RESULTS: A total of 66 patients (51.1 ± 9.4 years) and 88 controls (49.2 ± 10.5 years) were examined. The mild-moderate OSAS group and the severe OSAS group had no significant differences in measures of specular microscopy compared with the controls (ECD, p = 0.84; Hex, p = 0.18; CV, p = 0.41). The mean values of ECD, Hex, and CV were 2552.56 ± 302.49 cells/mm2, 54.13 ± 8.13%, and 36.41 ± 5.92, respectively, in the mild-moderate OSAS group; 2510.52 ± 377.12 cells/mm2, 54.85 ± 8.68%, and 34.77 ± 5.02, respectively, in the severe OSAS group; 2543.37 ± 286.94 cells/mm2, 51.89 ± 9.09%, and 36.03 ± 5.32, respectively, in the control group. CONCLUSIONS: There were no significant differences in corneal endothelial features between patients and controls. Although OSAS causes systemic hypoxia, its effects do not appear to result in corneal endothelial alterations detectable by specular microscopy.


Asunto(s)
Endotelio Corneal/diagnóstico por imagen , Endotelio Corneal/patología , Apnea Obstructiva del Sueño/complicaciones , Adulto , Estudios de Casos y Controles , Estudios Transversales , Femenino , Humanos , Masculino , Microscopía , Persona de Mediana Edad , Estudios Prospectivos
16.
Int Ophthalmol ; 40(11): 3023-3032, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32607948

RESUMEN

PURPOSE: Fabry disease (FD) is characterized by a deficiency in α-galactosidase A activity that leads to the cumulative deposition of unmetabolized glycosphingolipids within organs, including the vascular endothelium and the eyes. The purpose of this study was to assess the effects of FD on the retinal microvasculature, foveal avascular zone (FAZ), macular thickness and retinal nerve fiber layer (RNFL) using optical coherence tomography angiography (OCT-A). METHODS: Twenty-five patients (14 female and 11 male; mean age 33.16 ± 11.44) with genetically verified FD were compared with 37 age- and sex-matched healthy controls (mean age 32.36 ± 15.54). The vessel density (VD) values of the superficial and deep capillary plexuses (SCP and DCP), the area of the FAZ, the density of radial peripapillary capillaries (RPC), the macular thickness and the retinal nerve fiber layer thickness were measured by OCT-A examination. RESULTS: The patients showed significantly lower VD values than controls in the foveal regions of both SCP and the DCP (21.15 ± 5.56 vs. 23.79 ± 4.64 (p = 0.048), 37.92 ± 6.78 vs. 41.11 ± 5.59 (p = 0.048), respectively). The FAZ was significantly larger in the FD group than in the control group (0.3 ± 0.1 vs. 0.24 ± 0.08 (p = 0.011)). No significant difference was identified in measurements of RPC density, peripapillary RNFL thickness or macular thickness between the two groups (p > 0.05 for all). CONCLUSION: Decreased VD and an enlarged foveal avascular area suggest possible changes in the retinal microvasculature of patients with FD. OCT-A can serve as a useful, noninvasive, quantitative tool for diagnosing FD and monitoring its progression.


Asunto(s)
Enfermedad de Fabry , Tomografía de Coherencia Óptica , Adolescente , Adulto , Enfermedad de Fabry/diagnóstico por imagen , Femenino , Angiografía con Fluoresceína , Fóvea Central , Humanos , Masculino , Persona de Mediana Edad , Vasos Retinianos/diagnóstico por imagen , Adulto Joven
17.
Jpn J Ophthalmol ; 64(4): 392-397, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32112186

RESUMEN

PURPOSE: To investigate the associations between mean ocular perfusion pressure (MOPP) and several variables including body mass index (BMI), comorbid medical conditions and various ocular parameters in a population-based sample. STUDY DESIGN: Cross-sectional. METHODS: Data of 2091 healthy participants from a previous population based cross-sectional study were reviewed. Inclusion criteria were adults ≥40 years of age who were screened on-site for glaucoma. Data on medical history, height, weight, systolic and diastolic blood pressures (SBP and DBP, respectively) were obtained. A basic ocular examination was performed which included intraocular pressure (Tono-Pen XL, Reichert Technologies) and central corneal thickness (Pacline pachymetry;) measurement, slit-lamp examination and non-mydriatic optic disc photography (nonmydα fundus camera, Kowa). MOPP was calculated using the formula [2/3 x (DBP + 1/3(SBP-DBP)]-IOP and low MOPP was defined as MOPP ≤45 mmHg. RESULTS: Mean age of the subjects was 63.04 ± 9.7 years (range: 44 and 99 years) and the majority were women (74.1%, n = 1549). Mean MOPP values in normal weight (BMI < 25), overweight (BMI = 25-29.9) and in obese individuals were 46.9 ± 9.0 mmHg, 48.6 ± 9.2 mmHg and 50.7 ± 10.0 mmHg, respectively (p < 0.001, in all pairwise comparisons). In the multivariable logistic regression analysis, migraine and IOP elevation (per 1 mmHg increment) were significantly associated with a low MOPP (OR: 2.10 and 1.22, p = 0.008 and < 0.001, respectively). On the other hand, risk of low MOPP was reduced in subjects with hypertension, and with increasing age (per 1-year increment) and BMI (per 1-unit increment) (OR: 0.15, 0.97, and 0.95, respectively, and p < 0.001 for all). CONCLUSION: Migraine and elevated IOP increase the risk of low MOPP and this may have a causal relationship with impaired optic nerve head blood flow.


Asunto(s)
Presión Sanguínea/fisiología , Glaucoma/fisiopatología , Presión Intraocular/fisiología , Disco Óptico/irrigación sanguínea , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento/fisiología , Índice de Masa Corporal , Córnea/anatomía & histología , Paquimetría Corneal , Estudios Transversales , Femenino , Glaucoma/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Hipertensión Ocular/fisiopatología , Microscopía con Lámpara de Hendidura , Encuestas y Cuestionarios , Tonometría Ocular , Campos Visuales/fisiología
18.
Sleep ; 43(8)2020 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-32006429

RESUMEN

STUDY OBJECTIVES: The usage of wrist-worn wearables to detect sleep-wake states remains a formidable challenge, particularly among individuals with disordered sleep. We developed a novel and unbiased data-driven method for the detection of sleep-wake and compared its performance with the well-established Oakley algorithm (OA) relative to polysomnography (PSG) in elderly men with disordered sleep. METHODS: Overnight in-lab PSG from 102 participants was compared with accelerometry and photoplethysmography simultaneously collected with a wearable device (Empatica E4). A binary segmentation algorithm was used to detect change points in these signals. A model that estimates sleep or wake states given the changes in these signals was established (change point decoder, CPD). The CPD's performance was compared with the performance of the OA in relation to PSG. RESULTS: On the testing set, OA provided sleep accuracy of 0.85, wake accuracy of 0.54, AUC of 0.67, and Kappa of 0.39. Comparable values for CPD were 0.70, 0.74, 0.78, and 0.40. The CPD method had sleep onset latency error of -22.9 min, sleep efficiency error of 2.09%, and underestimated the number of sleep-wake transitions with an error of 64.4. The OA method's performance was 28.6 min, -0.03%, and -17.2, respectively. CONCLUSIONS: The CPD aggregates information from both cardiac and motion signals for state determination as well as the cross-dimensional influences from these domains. Therefore, CPD classification achieved balanced performance and higher AUC, despite underestimating sleep-wake transitions. The CPD could be used as an alternate framework to investigate sleep-wake dynamics within the conventional time frame of 30-s epochs.


Asunto(s)
Actigrafía , Trastornos del Sueño-Vigilia , Anciano , Algoritmos , Humanos , Masculino , Polisomnografía , Sueño
19.
Ticks Tick Borne Dis ; 11(3): 101373, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31964592

RESUMEN

This Turkey-based study investigated the presence of various tick-borne microorganisms in a broad-range of host-seeking ticks (n = 1019) that exhibit both hunter and ambusher characteristics. All collected ticks were analyzed individually via PCR-sequencing, resulting in the identification of 18 different microorganisms: six Babesia spp., including one putative novel species (Ba. occultans, Ba. crassa, Ba. rossi, Babesia sp. tavsan1, Babesia sp. tavsan2, and Babesia sp. nov.); six SFG rickettsiae (Ri. aeschlimannii, Ri. s. mongolitimonae, Ri. slovaca, Ri. raoultii, Ri. monacensis, and Ri. hoogstraalii); two Borrelia burgdorferi sensu lato spp. (Bo. afzelii and Bo. lusitaniae); two unnamed Hepatozoon spp.; Theileria annulata; and Hemolivia mauritanica. This provided evidence for the natural transstadial survival of these tick-borne microorganisms in adult ticks (in addition a nymph) of Turkey. Surprisingly, this study determined the presence of five different microorganisms (Ba. crassa, Ba. rossi, Babesia sp. Ucbas, Hepatozoon sp., and Ri. hoogstraalii) in host-seeking Haemaphysalis parva adults, for which poor data exist on its vectorial competence. Therefore, this study provides important data indicating the potential vectorial capacity of Ha. parva. This study also revealed the presence of the close ecological and evolutionary relationships between two important vector ticks, Hyalomma marginatum and Hy. aegyptium and determined genetic variations (distinct phylogenetic divergences inside the main clades) in some pathogenic SFG rickettsiae that are found in these ticks. Additionally, the presence of two Babesia species described very recently in hares with unknown vectors, namely Babesia sp. tavsan1 and Babesia sp. tavsan2, were detected for the first time in ticks. Finally, two unnamed Hepatozoon spp. were detected in Haemaphysalis ticks and their phylogenetic positions were demonstrated. Consequently, this study provides important data on the diversity of tick-borne microorganisms in host-seeking ticks and on potentially novel microorganisms (Babesia and Hepatozoon species) and their possible vectors (Ha. parva, Ha. sulcata, Hy. aegyptium, Hy. marginatum, and Rh. turanicus).


Asunto(s)
Babesia/aislamiento & purificación , Grupo Borrelia Burgdorferi/aislamiento & purificación , Rickettsia/aislamiento & purificación , Theileria annulata/aislamiento & purificación , Garrapatas/microbiología , Garrapatas/parasitología , Animales , Vectores de Enfermedades , Enfermedades por Picaduras de Garrapatas/microbiología , Enfermedades por Picaduras de Garrapatas/parasitología , Turquía
20.
Graefes Arch Clin Exp Ophthalmol ; 258(5): 1057-1064, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31915973

RESUMEN

PURPOSE: To investigate whether cornea verticillata affects corneal topography, tomography, densitometry, or biomechanics of Fabry patients with ocular manifestations and to compare these results with those obtained from healthy subjects. METHODS: This prospective, cross-sectional study included 23 Fabry patients (Fabry group) with cornea verticillata and the 37 age- and sex-matched healthy subjects (control group). After comprehensive ophthalmological examinations, corneal topography, tomography, and densitometry measurements were taken using Pentacam HR and corneal biomechanics were captured via Corvis ST for all participants. RESULTS: All the investigated topographic and tomographic values were similar in the eyes with Fabry disease (FD) and the controls (P > 0.05). The corneal densitometry values of patients with FD were statistically significantly higher in all the concentric zones and layers, except posterior 0-2 mm and posterior 2-6 mm zones, compared to the controls (P < 0.05). The mean values of A1 velocity, A2 velocity, deformation amplitude ratio, Corvis biomechanical index, tomographic and biomechanical index, and Stiffness parameter at the first applanation in the Fabry group were statistically significantly different compared to control group (P < 0.05). However, the mean values of A1 length, A2 length, and the biomechanically corrected intraocular pressure were similar between the groups (P = 0.317, P = 0.819, and P = 0.468; respectively). CONCLUSION: Although cornea verticillata associated with FD is not considered to affect vision, it is associated with increased light backscattering and reduced corneal transparency as well as altered corneal biomechanical properties.


Asunto(s)
Córnea/fisiopatología , Enfermedades de la Córnea/fisiopatología , Enfermedad de Fabry/fisiopatología , Adolescente , Adulto , Fenómenos Biomecánicos , Niño , Paquimetría Corneal , Topografía de la Córnea , Estudios Transversales , Densitometría , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tomografía de Coherencia Óptica , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...